Tendon graft fixation in anterior cruciate ligament reconstruction with cortical press-fit bolt
-
-
Abstract
Objective To study the clinical outcome of tendon graft fixation in anterior cruciate ligament(ACL) reconstruction with cortical press-fit bolt(CPB). Methods The femoral end was fixed with Endobutton+CPB,ACL was reconstructed by fixing tibia with Rigidfix from January 2010 and December 2010 in 17 patients(14 males and 3 females) at the age of 28.6 years(range 15-49 years).The forward shift of tibia was measured with Rolimeter and the knee function was assessed using the Lysholm scoring system before and after operation.The patients received X-ray and MRI examination after operation. Results The patients were followed up for 6.9 months(range 3-13 months) during which no infection and complications of nerve and blood vessels occurred.X-ray showed that CPB was replaced by creeping fibers 3 months after operation.Significant differences were found in forward shift of tibia before and after operation(P<0.01).However,no significant difference was observed in forward shift of tibia between the affected and healthy knees.The preoperative Lysholm score was 31.1±6.3 before operation and 85.2±6.9 after operation(P<0.001).The total excellent and good rate was 88.2%. Conclusion CPB fixation can meet the physiological demand of ACL reconstruction with a good histocompatibility.
-
-