Application of real time ultrasound-guided subclavian vein puncture in central vein catheterization
-
-
Abstract
Objective To assess the efficacy and safety of real time ultrasound-guided subclavian vein(SCV) puncture in central vein catheterization. Methods The successful rate of central vein catheterization,number of punctures,puncture time,and incidence of complications in 97 patients who underwent real time ultrasound-guided SCV puncture in central vein catheterization form September 2007 to December 2011 were analyzed. Results The successful rate of central vein catheterization was 100%,the number of punctures was 1-3(1.5±0.6),and the puncture time was 15-30 min(19.2±5.5min).The central vein catheter was inserted into the internal jugular vein in 2 patients(2%),thrombosis occurred in 1 patient(1%) after catheterization,and infection developed in 10 patients(10%) 1-80(32.9±25.7)days after catheterization. Conclusion Real time ultrasound-guided SCV is an effective and safe procedure for central venous catheterization.
-
-