郑娇娇, 王知力. 乳腺疾病中血浆外泌体miR-21的表达及其联合超声造影的诊断价值研究[J]. 解放军医学院学报. DOI: 10.12435/j.issn.2095-5227.2024.120
引用本文: 郑娇娇, 王知力. 乳腺疾病中血浆外泌体miR-21的表达及其联合超声造影的诊断价值研究[J]. 解放军医学院学报. DOI: 10.12435/j.issn.2095-5227.2024.120
ZHENG Jiaojiao, WANG Zhili. Study on the expression of plasma exosomal miR-21 in breast diseases and its diagnostic value in combination with contrast-enhanced ultrasound[J]. ACADEMIC JOURNAL OF CHINESE PLA MEDICAL SCHOOL. DOI: 10.12435/j.issn.2095-5227.2024.120
Citation: ZHENG Jiaojiao, WANG Zhili. Study on the expression of plasma exosomal miR-21 in breast diseases and its diagnostic value in combination with contrast-enhanced ultrasound[J]. ACADEMIC JOURNAL OF CHINESE PLA MEDICAL SCHOOL. DOI: 10.12435/j.issn.2095-5227.2024.120

乳腺疾病中血浆外泌体miR-21的表达及其联合超声造影的诊断价值研究

Study on the expression of plasma exosomal miR-21 in breast diseases and its diagnostic value in combination with contrast-enhanced ultrasound

  • 摘要:
    背景  乳腺癌早期诊断对其预后至关重要,超声造影、miR-21水平均有助于乳腺癌的早期诊断,但miR-21联合常规超声(ultrasound,US)和超声造影(contrast-enhanced ultrasound,CEUS)是否可以进一步提高乳腺癌的早期诊断准确性尚不清楚。
    目的  分析常规超声及超声造影联合血浆外泌体miR21在乳腺疾病诊断中的应用价值。
    方法 本研究收集2022年12月至2023年5月解放军总医院超声诊断科行乳腺常规超声、CEUS检查、miR-21检测并有明确病理结果的患者306例。对比分析常规超声、超声造影、miR-21及联合诊断对乳腺良恶病变的诊断效能。
    结果  乳腺良性病变182例,平均年龄(43.62 ± 11.38)岁,恶性病变124例,平均年龄(51.98 ± 10.56)岁,良性(P<0.001);乳腺恶性组血浆外泌体miR-21相对表达量1.222(IQR:1.050 ~ 1.467)显著高于良性组0.780(IQR:0.630 ~ 0.960)(P<0.001)。常规超声诊断乳腺癌的敏感度为70.1%、特异度为83.5%、准确性为78.1%、受试者工作特征曲线下面积(Area under the receiver operating characteristic curve,AUC)为0.803;常规超声联合超声造影诊断乳腺癌的敏感度为81.5%、特异度为87.4%、准确性为85.0%、AUC为0.898;miR-21联合常规超声和超声造影诊断乳腺癌的敏感度为91.1%、特异度为85.7%、准确性为87.9%、AUC为0.948。miR-21联合常规超声和超声造影的诊断效能显著高于常规超声(P<0.001)和常规超声联合超声造影(P<0.001)。
    结论  超声造影联合血浆外泌体miR-21可以显著提高乳腺病变的诊断效能。

     

    Abstract:
    background  Early diagnosis of breast cancer is crucial for its prognosis. Both contrast-enhanced ultrasound and miR-21 levels contribute to the early diagnosis of breast cancer. However, it is unclear whether the combination of miR-21 with conventional ultrasound (US) and contrast-enhanced ultrasound (CEUS) can further improve the accuracy of early diagnosis of breast cancer.
    Objective To analyze the application value of US and CEUS combined with plasma exosomes miR21 in the diagnosis of breast diseases.
    Methods From December 2022 to April 2023, 306 patients (182 benign and 124 malignant) who underwent routine breast ultrasound, CEUS examination, miR-21 test and had clear pathological results in the Department of Ultrasound Diagnosis of Chinese PLA General Hospital were collected prospectively. The diagnostic efficacy of conventional ultrasound, contrast-enhanced ultrasound, and miR-21 in breast lesions was compared and analyzed.
    Results The sensitivity, specificity, accuracy and the area under the curve (AUC) of routine ultrasound in the diagnosis of breast cancer were 70.1%, 83.5%, 78.1% and 0.803, respectively; The sensitivity, specificity, accuracy and AUC of conventional ultrasound combined with contrast-enhanced ultrasound in the diagnosis of breast cancer were 81.5%, 87.4%, 85.0% and 0.898 respectively; The sensitivity, specificity, accuracy and AUC of miR-21 combined with conventional ultrasound and contrast-enhanced ultrasound in the diagnosis of breast cancer were 91.1%, 85.7%, 87.9% and 0.948 respectively. The diagnostic efficacy of miR-21 combined with conventional ultrasound and contrast-enhanced ultrasound was significantly higher than that of conventional ultrasound (P <0.001) and conventional ultrasound combined with contrast-enhanced ultrasound (P <0.001).
    Conclusion  The combination of contrast-enhanced ultrasound and plasma exosomes miR21 can significantly improve the diagnostic efficacy of breast lesions.

     

/

返回文章
返回