胸椎半侧骨骺加压矫形钉固定后对山羊脊柱即时稳定性的影响

The effect of immediate stability of goats′ thoracic vertebra after implanting hemiepiphyseal compression staples

  • 摘要: 目的: 测定山羊胸椎连续多节段半侧骨骺加压矫形钉固定即刻脊柱的刚度值,通过生物力学评价矫形钉对固定节段稳定性的影响。方法: 6具2~3个月山羊T6T11新鲜脊柱标本,每具分为正常状态,单钉状态(跨每个椎间隙植入1枚矫形钉),双钉状态(跨每个椎间隙植入2枚矫形钉),先后测试每种状态下,6具标本在左右旋转,左右侧弯,前曲,后伸6个方向上脊柱标本的刚度。结果: 在左、右旋转方向上,单钉、双钉状态脊柱的刚度值与正常状态无差别(P>0.05);在左、右侧弯、前屈、后伸4个方向上,单钉、双钉状态脊柱的刚度值低于正常状态(P<0.05)。结论: 体外实验证明,固定节段脊柱即刻稳定性比正常状态降低。

     

    Abstract: Objective: To test the stiffness of continuous multilevel thoracic vertebra in goats immediately after implanting hemiepiphyseal compression staples and evaluate the stability of fixed segments by biomechanics. Methods: Six fresh specimens of thoracic vertebrae(T6-T11) from 6 goats(age 2-3 months) were divided into three groups: native,single(one staple was implanted spanning each disc continually),and double(two staples were implanted spanning each disc continually).With each group,the stiffness of fixed segments during left and right rotation,left and right bending,flexion and extension were tested. Results: During left and right rotation,the stiffness in segments with single and double staples was not significantly different from that in native segment(P>0.05).During left and right bending,flexion,extension,the stiffness in segments with single and double staples was decreased as compared to that in native segment(P<0.05). Conclusion: In vitro,the immediate stability of fixed spinal segments is lower than that in normal thoracic vertebra in the goat.

     

/